Tali Weiss
Weizmann Institute of Science
The department of Brain Sciences
Sample in glass vial
20ml
Vacuum- assisted sorbent sampling
Sample details
Apple, red
Predicting perception of naturalistic odors
2025-09-18
Sample in glass vial
20ml
Yes
No
Fresh, Chopped
No
No
Sampling method
Vacuum- assisted sorbent sampling
2
1
Tenax GR
100
35/60
2
Carbograph 5TD
100
40/60
89mm
22000ml
-0.08MPa
960min
2min
50ml/min
Centri
2
2min
150°C
50ml/min
0ml/min
2min
240°C
50ml/min
0ml/min
GC-MS
Markes focusing trap
UNITY-T12ME-2S Material emissions, C4 - C32
1min
40ml/min
10°C
100°C/s
240°C
3min
Yes
50ml/min
DB-WAX Ultra-inert
1.29ml/min
30m
0.25mm
0.5μm
He
BenchTOF2 (SepSolve)
30-300
11Hz
-70eV
Tali Weiss
Weizmann Institute of Science
The department of Brain Sciences
Sample in glass vial
20ml
Vacuum- assisted sorbent sampling
Sample details
Apple, red
Predicting perception of naturalistic odors
2025-09-24
Sample in glass vial
20ml
Yes
No
Fresh, Chopped
No
No
Sampling method
Vacuum- assisted sorbent sampling
2
1
Tenax GR
100
35/60
2
Carbograph 5TD
100
40/60
89mm
22000ml
-0.08MPa
120min
2min
50ml/min
Centri
2
2min
150°C
50ml/min
0ml/min
2min
240°C
50ml/min
0ml/min
GC-MS
Markes focusing trap
UNITY-T12ME-2S Material emissions, C4 - C32
1min
40ml/min
10°C
100°C/s
240°C
3min
Yes
40ml/min
DB-WAX Ultra-inert
1.29ml/min
30m
0.25mm
0.5μm
He
BenchTOF2 (SepSolve)
30-300
8Hz
-70eV
Tali Weiss
Weizmann Institute of Science
Department of Brain Sciences
Sample in glass vial
20ml
1g
Static headspace using syringe injection
Sample details
Syrup, raspberry flavor
Predicting perception of naturalistic odors
2025-10-29
Sample in glass vial
20ml
No
1g
No
liqude
No
Sampling method
Static headspace using syringe injection
Yes
Centri 360
Yes
0.2min
50°C
Yes
5ml
25°C
5ml
Yes
5
1min
250°C
2min
No
GC-MS
Markes focusing trap
UNITY-T12ME-2S Material emissions, C4 - C32
1min
50ml/min
10°C
100°C/s
250°C
3min
Yes
30ml/min
DB-WAX-UI
1.77ml/min
30m
0.25mm
0.5μm
He
BenchTOF2 (SepSolve)
30-300
8Hz
-70eV
Eunyeong
Max Planck Institute for Chemistry
Jonathan Williams Group / Atmospheric Chemistry
Sample in glass vial
1000ml
Pump - sorbent tubes
Sample details
Tomato
Object_smell
2026-01-21
Sample in glass vial
1000ml
Yes
No
Chopped
No
No
Sampling method
Pump - sorbent tubes
2
1
Tenax TA
150
35/60
2
Carbograph 5
150
40/60
89mm
1000ml
200ml/min
No
No
Markes TD100-xr
1
5min
250°C
50ml/min
50ml/min
GC-MS
Markes focusing trap
materials emissions
1min
50ml/min
-20°C
45°C/s
260°C
5min
Yes
49ml/min
ZB-624plus
1ml/min
7.5psi
30m
0.25mm
1.4μm
He
QTOF (Agilent)
29-350
5Hz
70eV
Eunyeong
Max Planck Institute for Chemistry
Jonathan Williams Group / Atmospheric Chemistry
Sample in glass vial
1000ml
Pump - sorbent tubes
Sample details
Glue
Object_smell
2026-01-21
Sample in glass vial
1000ml
Yes
No
Fresh
{Empty}
Sampling method
Pump - sorbent tubes
2
1
Tenax TA
150
35/60
2
Carbograph 5
150
40/60
89mm
1000ml
200ml/min
No
No
Markes TD100-xr
1
5min
250°C
50ml/min
50ml/min
GC-MS
Markes focusing trap
materials emissions
1min
50ml/min
-20°C
45°C/s
260°C
5min
Yes
49ml/min
ZB-624plus
1ml/min
7.5psi
30m
0.25mm
1.4μm
He
QTOF (Agilent)
29-350
5Hz
70eV
Eunyeong
Max Planck Institute for Chemistry
Jonathan Williams Group / Atmospheric Chemistry
Sample in glass vial
1000ml
Pump - sorbent tubes
Sample details
Laundry detergent
Object_smell
2026-01-21
Sample in glass vial
1000ml
Yes
No
Fresh
{Empty}
Sampling method
Pump - sorbent tubes
2
1
Tenax TA
150
35/60
2
Carbograph 5
150
40/60
89mm
1000ml
200ml/min
No
No
Markes TD100-xr
1
5min
250°C
50ml/min
50ml/min
GC-MS
Markes focusing trap
materials emissions
1min
50ml/min
-20°C
45°C/s
260°C
5min
Yes
49ml/min
ZB-624plus
1ml/min
7.5psi
30m
0.25mm
1.4μm
He
QTOF (Agilent)
29-350
5Hz
70eV
Eunyeong
Max Planck Institute for Chemistry
Jonathan Williams Group / Atmospheric Chemistry
Sample in glass vial
1000ml
Pump - sorbent tubes
Sample details
nail polish
Object_smell
2026-01-21
Sample in glass vial
1000ml
Yes
No
Fresh
{Empty}
Sampling method
Pump - sorbent tubes
2
1
Tenax TA
150
35/60
2
Carbograph 5
150
40/60
89mm
1000ml
200ml/min
No
No
Markes TD100-xr
1
5min
250°C
50ml/min
50ml/min
GC-MS
Markes focusing trap
materials emissions
1min
50ml/min
-20°C
45°C/s
260°C
5min
Yes
49ml/min
ZB-624plus
1ml/min
7.5psi
30m
0.25mm
1.4μm
He
QTOF (Agilent)
29-350
5Hz
70eV
Itay Gonda
Newe-Ya’ar Research Center, Volcani Institute
Aromatic and Medicinal Plants Unit
Sample in glass vial
0.03ml
0.03g
derivatization_and_liquid_injection
Sample details
Essential oil of Spanish lavender (Lavandula stoechas)
Sample in glass vial
0.03ml
No
0.03g
No
Sampling method
derivatization_and_liquid_injection
GC-MS
Rxi-5-Sil ms
2.1606ml/min
18.154psi
30m
0.25mm
0.25μm
He
Quadrupole-MS (Agilent)
41-300
8Hz
-70eV
Eunyeong
Max Planck Institute for Chemistry
Jonathan Williams Group / Atmospheric Chemistry
Sample in glass vial
1000ml
Pump - sorbent tubes
Sample details
Onion
Object_smell
2026-01-21
Sample in glass vial
1000ml
Yes
No
Chopped
No
No
Sampling method
Pump - sorbent tubes
2
1
Tenax TA
150
35/60
2
Carbograph 5
150
40/60
89mm
1000ml
200ml/min
No
No
Markes TD100-xr
1
5min
250°C
50ml/min
50ml/min
GC-MS
Markes focusing trap
materials emissions
1min
50ml/min
-20°C
45°C/s
260°C
5min
Yes
49ml/min
ZB-624plus
1ml/min
7.5psi
30m
0.25mm
1.4μm
He
QTOF (Agilent)
29-350
5Hz
70eV
Eunyeong
Max Planck Institute for Chemistry
Jonathan Williams Group / Atmospheric Chemistry
Sample in glass vial
1000ml
Pump - sorbent tubes
Sample details
Garlic
Object_smell
2026-01-21
Sample in glass vial
1000ml
Yes
No
Chopped
No
No
Sampling method
Pump - sorbent tubes
2
1
Tenax TA
150
35/60
2
Carbograph 5
150
40/60
89mm
1000ml
200ml/min
No
No
Markes TD100-xr
1
5min
250°C
50ml/min
50ml/min
GC-MS
Markes focusing trap
materials emissions
1min
50ml/min
-20°C
45°C/s
260°C
5min
Yes
49ml/min
ZB-624plus
1ml/min
7.5psi
30m
0.25mm
1.4μm
He
QTOF (Agilent)
29-350
5Hz
70eV