Shiri Karagach Rubin
Weizmann Institute of Science
The department of Brain Sciences
Sample in glass vial
10ml
Dynamic headspace
Sample details
Plastic Wrapper New Bed Sheets
2021-11-02
Sample in glass vial
10ml
Yes
No
Fresh
No
Sampling method
Dynamic headspace
Yes
Gerstel MPS
2
1
Tenax TA
60/80
2
Carbopack X
40/60
60mm
500ml
50ml/min
No
No
No
1min
50ml/min
Gerstle TDU2
1
250°C
GC-MS
Cooled Injection System
-10°C
250°C
No
DB-5
30m
He
Quadrupole-MS Agilent
40-450
1Hz
-70eV
Shiri Karagach Rubin
Weizmann Institute of Science
The department of Brain Sciences
Sample in glass vial
10ml
Dynamic headspace
Sample details
New Bed Sheets
2021-11-02
Sample in glass vial
10ml
Yes
No
Fresh
No
Sampling method
Dynamic headspace
Yes
Gerstel MPS
2
1
Tenax TA
60/80
2
Carbopack X
40/60
60mm
500ml
50ml/min
No
No
No
1min
50ml/min
Gerstle TDU2
1
250°C
GC-MS
Cooled Injection System
-10°C
250°C
No
DB-5
30m
He
Quadrupole-MS Agilent
40-450
1Hz
-70eV
Heather Spooner
University of Reading, England
Food and Nutritional Sciences
Sample in glass vial
18ml
1g
Solid-Phase Microextraction (SPME)
Sample details
Alkane (syrups)
Parosmia Project
2022-03-21
Sample in glass vial
18ml
No
1g
Yes
4°C
Diethyl ether
{Empty}
Sampling method
Solid-Phase Microextraction (SPME)
No
triple phase DVB/Carboxen/PDMS 1 cm
DVB 50 um Carboxen 30 um PDMS 30 um
DVB 50 um Carboxen 30 um PDMS 30 um
30um
40°C
20min
Yes
20min
40°C
20min
250°C
Yes
500rpm
GC-MS
HP-5 5% Phenyl Methyl Siloxan
0.9ml/min
30m
0.25mm
1μm
He
Quadrupole MS 5975C (Agilent)
20-280
0.69Hz
-70eV
Shiri Karagach Rubin
Weizmann Institute of Science
The department of Brain Sciences
Sample in glass vial
20ml
0.058g
Dynamic headspace
Sample details
Baby Poop
Poop in babies
2025-01-20
Sample in glass vial
20ml
No
0.058g
No
Fresh
No
Sampling method
Dynamic headspace
Yes
Gerstel MPS
2
1
Tenax GR
2
Carbopack B
60mm
No
No
No
Gerstle TDU2
1
GC-MS
Cooled Injection System
No
DB-5
30m
He
Quadrupole-MS Agilent
35-200
1Hz
-70eV
Tali Weiss
Weizmann Institute of Science
The department of Brain Sciences
Sample in glass vial
20ml
6g
Static headspace using syringe injection
Sample details
Canned tuna (in oil)
Predicting perception from enose
2025-01-20
Sample in glass vial
20ml
No
6g
No
Chopped
No
No
Sampling method
Static headspace using syringe injection
Yes
Centri 360
No
5ml
60°C
20ml
Yes
4
1min
200°C
2min
No
GC-MS
Markes focusing trap
UNITY-T12ME-2S Material emissions, C4 - C32
3min
40ml/min
10°C
100°C/s
220°C
3min
Yes
20ml/min
HP-5ms Ultra Inert
1ml/min
30m
0.25mm
0.25μm
He
BenchTOF2 (SepSolve)
35-200
10Hz
-70eV
Tali Weiss
Weizmann Institute of Science
The department of Brain Sciences
Sample in glass vial
20ml
3.7g
Static headspace using syringe injection
Sample details
Canned tuna (in oil)
Predicting perception of naturalistic odors
2025-01-19
Sample in glass vial
20ml
No
3.7g
No
Chopped
No
No
Sampling method
Static headspace using syringe injection
Yes
Centri 360
No
5ml
50°C
10ml
Yes
2
1min
180°C
2min
No
GC-MS
Markes focusing trap
UNITY-T12ME-2S Material emissions, C4 - C32
3min
40ml/min
10°C
100°C/s
200°C
3min
Yes
20ml/min
HP-5ms Ultra Inert
1ml/min
30m
0.25mm
0.25μm
He
BenchTOF2 (SepSolve)
35-200
10Hz
-70eV
Heather Spooner
University of Reading, Reading, Berkshire, United Kingdom
Department of Food and Nutritional Sciences
Sample in glass vial
18ml
1g
Solid-Phase Microextraction (SPME)
Sample details
Vanilla syrup
Parosmia Project
2022-03-21
Sample in glass vial
18ml
No
1g
Yes
4°C
syrup
{Empty}
Sampling method
Solid-Phase Microextraction (SPME)
No
triple phase DVB/Carboxen/PDMS 1 cm
DVB 50 um Carboxen 30 um PDMS 30 um
DVB 50 um Carboxen 30 um PDMS 30 um
30um
40°C
20min
Yes
20min
40°C
20min
250°C
Yes
500rpm
GC-MS
HP-5 5% Phenyl Methyl Siloxan
0.9ml/min
30m
0.25mm
1μm
He
Quadrupole MS 5975C (Agilent)
20-280
0.69Hz
-70eV
Heather Spooner
University of Reading, Reading, Berkshire, United Kingdom
Department of Food and Nutritional Sciences
Sample in glass vial
18ml
1g
Solid-Phase Microextraction (SPME)
Sample details
Hazelnut syrup
Parosmia Project
2022-03-21
Sample in glass vial
18ml
No
1g
Yes
4°C
syrup
{Empty}
Sampling method
Solid-Phase Microextraction (SPME)
No
triple phase DVB/Carboxen/PDMS 1 cm
DVB 50 um Carboxen 30 um PDMS 30 um
DVB 50 um Carboxen 30 um PDMS 30 um
30um
40°C
20min
Yes
20min
40°C
20min
250°C
Yes
500rpm
GC-MS
HP-5 5% Phenyl Methyl Siloxan
0.9ml/min
30m
0.25mm
1μm
He
Quadrupole MS 5975C (Agilent)
20-280
0.69Hz
-70eV
Heather Spooner
University of Reading, Reading, Berkshire, United Kingdom
Department of Food and Nutritional Sciences
Sample in glass vial
18ml
1g
Solid-Phase Microextraction (SPME)
Sample details
Gingerbread syrup
Parosmia Project
2022-03-21
Sample in glass vial
18ml
No
1g
Yes
4°C
syrup
{Empty}
Sampling method
Solid-Phase Microextraction (SPME)
No
triple phase DVB/Carboxen/PDMS 1 cm
DVB 50 um Carboxen 30 um PDMS 30 um
DVB 50 um Carboxen 30 um PDMS 30 um
30um
40°C
20min
Yes
20min
40°C
20min
250°C
Yes
500rpm
GC-MS
HP-5 5% Phenyl Methyl Siloxan
0.9ml/min
30m
0.25mm
1μm
He
Quadrupole MS 5975C (Agilent)
20-280
0.69Hz
-70eV
Heather Spooner
University of Reading, Reading, Berkshire, United Kingdom
Department of Food and Nutritional Sciences
Sample in glass vial
18ml
1g
Solid-Phase Microextraction (SPME)
Sample details
Caramel syrup
Parosmia Project
2022-03-21
Sample in glass vial
18ml
No
1g
Yes
4°C
syrup
{Empty}
Sampling method
Solid-Phase Microextraction (SPME)
No
triple phase DVB/Carboxen/PDMS 1 cm
DVB 50 um Carboxen 30 um PDMS 30 um
DVB 50 um Carboxen 30 um PDMS 30 um
30um
40°C
20min
Yes
20min
40°C
20min
250°C
Yes
500rpm
GC-MS
HP-5 5% Phenyl Methyl Siloxan
0.9ml/min
30m
0.25mm
1μm
He
Quadrupole MS 5975C (Agilent)
20-280
0.69Hz
-70eV