Faith Zillinger
Michigan State University
Department of Food Science and Human Nutrition
Sample in glass vial
20ml
5g
Solid-Phase Microextraction (SPME)
Sample details
Chickpea Roasted Porridge 2023
Pulse Flours
https://doi.org/10.1111/1750-3841.70608
Sample in glass vial
20ml
No
5g
No
Fresh, Crushed
No
Yes
Sodium chloride
Sampling method
Solid-Phase Microextraction (SPME)
Yes
Gerstel MPS
DVB/CAR/PDMS
30um
50°C
30min
Yes
30min
50°C
0.3min
200°C
No
GC-MS
Cooled Injection System
-196°C
{Empty}
HP-5
1.8ml/min
30m
.25mm
.25μm
He
TOF (Leco)
29-400
20Hz
-70eV
Faith Zillinger
Michigan State University
Department of Food Science and Human Nutrition
Sample in glass vial
20ml
5g
Solid-Phase Microextraction (SPME)
Sample details
Chickpea Boiled Pulse 2023
Pulse Flours
https://doi.org/10.1111/1750-3841.70608
Sample in glass vial
20ml
No
5g
No
Fresh, Crushed
No
No
Sampling method
Solid-Phase Microextraction (SPME)
Yes
Gerstel MPS
DVB/CAR/PDMS
30um
50°C
30min
Yes
30min
50°C
0.3min
200°C
No
GC-MS
Cooled Injection System
-196°C
{Empty}
HP-5
1.8ml/min
30m
.25mm
.25μm
He
TOF (Leco)
29-400
20Hz
-70eV
Faith Zillinger
Michigan State University
Department of Food Science and Human Nutrition
Sample in glass vial
20ml
2g
Solid-Phase Microextraction (SPME)
Sample details
Chickpea Unroasted Flour 2023
Pulse Flours
https://doi.org/10.1111/1750-3841.70608
Sample in glass vial
20ml
No
2g
Yes
2°C
525600Hours
Dried
Sampling method
Solid-Phase Microextraction (SPME)
Yes
Gerstel MPS
DVB/CAR/PDMS
30um
50°C
30min
Yes
30min
50°C
0.3min
200°C
No
GC-MS
Cooled Injection System
-196°C
{Empty}
HP-5
1.8ml/min
30m
.25mm
.25μm
He
TOF (Leco)
29-400
20Hz
-70eV
Faith Zillinger
Michigan State University
Department of Food Science and Human Nutrition
Sample in glass vial
20ml
2g
Solid-Phase Microextraction (SPME)
Sample details
Chickpea Roasted Flour 2023
Pulse Flours
https://doi.org/10.1111/1750-3841.70608
Sample in glass vial
20ml
No
2g
Yes
2°C
525600Hours
Dried
Sampling method
Solid-Phase Microextraction (SPME)
Yes
Gerstel MPS
DVB/CAR/PDMS
30um
50°C
30min
Yes
30min
50°C
0.3min
200°C
No
GC-MS
Cooled Injection System
-196°C
{Empty}
HP-5
1.8ml/min
30m
.25mm
.25μm
He
TOF (Leco)
29-400
20Hz
-70eV
Faith Zillinger
Michigan State University
Department of Food Science and Human Nutrition
Sample in glass vial
20ml
5g
Solid-Phase Microextraction (SPME)
Sample details
Navy Bean Unroasted Porridge 2023
Pulse Flours
https://doi.org/10.1111/1750-3841.70608
Sample in glass vial
20ml
No
5g
No
Fresh, Crushed
No
Yes
Sodium chloride
Sampling method
Solid-Phase Microextraction (SPME)
Yes
Gerstel MPS
DVB/CAR/PDMS
30um
50°C
30min
Yes
30min
50°C
0.3min
200°C
No
GC-MS
Cooled Injection System
-196°C
{Empty}
HP-5
1.8ml/min
30m
.25mm
.25μm
He
TOF (Leco)
29-400
20Hz
-70eV
Faith Zillinger
Michigan State University
Department of Food Science and Human Nutrition
Sample in glass vial
20ml
5g
Solid-Phase Microextraction (SPME)
Sample details
Navy Bean Roasted Porridge 2023
Pulse Flours
https://doi.org/10.1111/1750-3841.70608
Sample in glass vial
20ml
No
5g
No
Fresh, Crushed
No
Yes
Sodium chloride
Sampling method
Solid-Phase Microextraction (SPME)
Yes
Gerstel MPS
DVB/CAR/PDMS
30um
50°C
30min
Yes
30min
50°C
0.3min
200°C
No
GC-MS
Cooled Injection System
-196°C
{Empty}
HP-5
1.8ml/min
30m
.25mm
.25μm
He
TOF (Leco)
29-400
20Hz
-70eV
Faith Zillinger
Michigan State University
Department of Food Science and Human Nutrition
Sample in glass vial
20ml
5g
Solid-Phase Microextraction (SPME)
Sample details
Navy Bean Boiled Pulse 2023
Pulse Flours
https://doi.org/10.1111/1750-3841.70608
Sample in glass vial
20ml
No
5g
No
Fresh, Crushed
No
No
Sampling method
Solid-Phase Microextraction (SPME)
Yes
Gerstel MPS
DVB/CAR/PDMS
30um
50°C
30min
Yes
30min
50°C
0.3min
200°C
No
GC-MS
Cooled Injection System
-196°C
{Empty}
HP-5
1.8ml/min
30m
.25mm
.25μm
He
TOF (Leco)
29-400
20Hz
-70eV
Faith Zillinger
Michigan State University
Department of Food Science and Human Nutrition
Sample in glass vial
20ml
2g
Solid-Phase Microextraction (SPME)
Sample details
Navy Bean Unroasted Flour 2023
Pulse Flours
https://doi.org/10.1111/1750-3841.70608
Sample in glass vial
20ml
No
2g
Yes
2°C
525600Hours
Dried
Sampling method
Solid-Phase Microextraction (SPME)
Yes
Gerstel MPS
DVB/CAR/PDMS
30um
50°C
30min
Yes
30min
50°C
0.3min
200°C
No
GC-MS
Cooled Injection System
-196°C
{Empty}
HP-5
1.8ml/min
30m
.25mm
.25μm
He
TOF (Leco)
29-400
20Hz
-70eV
Faith Zillinger
Michigan State University
Department of Food Science and Human Nutrition
Sample in glass vial
20ml
2g
Solid-Phase Microextraction (SPME)
Sample details
Navy Bean Roasted Flour 2023
Pulse Flours
https://doi.org/10.1111/1750-3841.70608
Sample in glass vial
20ml
No
2g
Yes
2°C
525600Hours
Dried
Sampling method
Solid-Phase Microextraction (SPME)
Yes
Gerstel MPS
DVB/CAR/PDMS
30um
50°C
30min
Yes
30min
50°C
0.3min
200°C
No
GC-MS
Cooled Injection System
-196°C
{Empty}
HP-5
1.8ml/min
30m
.25mm
.25μm
He
TOF (Leco)
29-400
20Hz
-70eV
Faith Zillinger
Michigan State University
Department of Food Science and Human Nutrition
Sample in glass vial
20ml
5g
Solid-Phase Microextraction (SPME)
Sample details
Manteca Bean Boiled Pulse 2022
Pulse Flours
https://doi.org/10.1111/1750-3841.70608
Sample in glass vial
20ml
No
5g
No
Fresh, Crushed
No
No
Sampling method
Solid-Phase Microextraction (SPME)
Yes
Gerstel MPS
DVB/CAR/PDMS
30um
50°C
30min
Yes
30min
50°C
0.3min
200°C
No
GC-MS
Cooled Injection System
-196°C
{Empty}
HP-5
1.8ml/min
30m
.25mm
.25μm
He
TOF (Leco)
29-400
20Hz
-70eV